Battery: Component Tests and General Diagnostics
Battery, Load Testing With Midtronics Diagnostic Conductance Charging Station INC-940

Battery Testing

Maintenance-free batteries must not be opened. Otherwise, the warranty is void.

Battery, Load Testing with Midtronics Diagnostic Conductance Charging Station INC-940

The Midtronics Diagnostic Conductance Charging Station (INC-940) (also known as "inCHARGE 940" ) integrates battery conductance and load
testing with charging.

By checking a battery's current draw capacity during charging, a decision can be made as to whether a severely discharged battery => [ Totally
Discharged Batteries, Charging ] See: Battery Charging can be made usable again by recharging, or if it must be replaced.

CAUTION!
Risk of injury from battery acid.

‹› Prior to handling or servicing batteries, read, understand and observe the Warnings and Safety Measures for lead-acid batteries for

lead-acid batteries => [ Safety Precautions ] See: Description and Operation/Battery!

‹› Wear protective eyewear and clothing => [ Protect against injury by using protective

eyewear and clothing. ] See: Description and Operation/Battery. 

‹› On non-maintenance-free batteries, the sealing plugs must be installed tightly.

‹› Provide sufficient ventilation.

‹› If the magic eye has no color or is light yellow, the battery may not be tested or charged. Jump starting must not be used! There is a

risk of explosion during testing, charging or jump starting. The battery must be replaced.

‹› DO NOT battery test batteries which are gassing. Otherwise there is a risk of explosion. 

‹› Rapid-charging batteries => [ Battery, Quick Charging ] See: Battery Charging.

‹› Dispose of electrolyte (sulfuric acid/water mixture) properly! Waste electrolyte must only be disposed of in appropriate waste disposal

sites. Refer to local regulations pertaining to electrolyte disposal. 

‹› The following notes and procedures must be followed to ensure correct measurements.

CAUTION!
Risk of damaging AGM batteries.

‹› Specific charging procedures are required for AGM batteries. 

Special tools, testers and auxiliary items required

‹› Midtronics Diagnostic Conductance Charging Station ( INC-940) (VAS tester illustrated here for reference only)

Prerequisite

Battery temperature must be at least +10 °C.

Procedure

CAUTION!
‹› Switch off all electrical consumers. 

‹› Switch ignition off and remove ignition key. 

‹› Refer to Midtronics Diagnostic Conductance Charging Station (INC-940) Instruction Manual.

-

Perform any model-specific preparations necessary to gain access to battery terminals or battery jump-start terminals.

-

Connect tester cable clamps to battery terminals => INC-940 Instruction Manual. Tester leads must be securely fastened and make proper contact

Battery, Testing With Midtronics Battery/Starting/Charging System Analyzer MCR340A|Page 6008 > < Battery, Testing With Midtronics Battery/Starting/Charging System Analyzer MCR340A|Page 6006