audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Maintenance-Free Batteries > < Lead-Acid Battery Without Visual Indicator, Checking|Page 6021
Page 2
background image

‹› The sealing plugs must be equipped with an O-ring.

-

Thread in battery cell sealing plugs.

Electrolyte level too low

If the electrolyte level is too low, a loss of battery capacity (power) occurs due to cell plates drying out. If the cell plates are not surrounded by
electrolyte (sulfuric acid-water mixture), the plates, plate straps, and cell connectors will corrode. The corrosion damages battery operation, the battery
can no longer be used.

-

If electrolyte level is too low, use battery filler (VAS 5045) to add distilled water until max mark is reached. 

‹› The filler neck of the Battery filler (VAS 5045 )is designed to prevent over-filling of the battery cell and electrolyte leakage. The flow of distilled

water into the battery cell is interrupted on reaching the max. level.

‹› Always use distilled water for topping up to prevent electrolyte contamination which results in increased self-discharge.

Maintenance-Free Batteries > < Lead-Acid Battery Without Visual Indicator, Checking|Page 6021