audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Condenser HVAC|Locations|Page 3802 > < Compressor Clutch Relay|Locations
Page 1
background image

Condenser HVAC: Locations

Cooling Fan/Radiator Assembly

1

Coolant pipe

2

Connector
‹› For Engine Coolant Level (ECL) warning switch -F66- in expansion tank

3

Expansion tank
‹› With Engine Coolant Level (ECL) warning switch -F66-

4

Cap

5

10 Nm (7 ft lb)

6

Fan with viscous clutch
‹› "FRONT" marking on outer fan ring must point in direction of travel
‹› Switching temperature 76° ± 4°C (169° ± 39°F) ambient temperature at viscous clutch
‹› Tightening torque depends on tools used 
‹› Right-hand thread

7

Fan frame

8

10 Nm (7 ft lb)

9

Coolant Fan Control (FC) thermo- switches -F18- and -F54-
‹› 25 Nm (18 ft lb)
‹› Switching temperatures:

1 =1st stage:

on at 92°-97°C (198°-207°F)
off at 84°-91°C (183°-196°F)

2 = 2nd stage:

on at 99°-105°C (210°-221°F)
off at 91°-98°C (196°-208°F)

+ = Battery Positive Voltage (B+)

Condenser HVAC|Locations|Page 3802 > < Compressor Clutch Relay|Locations