audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Relays and Modules - HVAC > < High Pressure Sensor / Switch, HVAC|Service and Repair
Page 1
background image

Low Pressure Sensor / Switch: Service and Repair

Function

-

Switches A/C compressor clutch OFF when A/C system suction pressure is too low (protects compressor when refrigerant system is discharged).

-

Switch opens (compressor OFF): 1.6-1.7 bar (23-25 psi).

-

Switch closes (compressor ON): 3.1-3.6 bar (45-52 psi).

-

Located in plenum chamber, right.

Removing And Installing

-

Remove plenum tray.

-

Remove A/C refrigerant low pressure switch. Refrigerant system remains closed (valve under switch).

-

Install new O-ring -A- (9.3 mm x 1.8 mm). Tightening torque: 5 Nm (44 in lb).

NOTE:  Only use O-rings specified for use with R-12 refrigerant and refrigerant oil.

-

DO NOT reuse O-rings, always replace.

-

Lubricate O-rings with A/C refrigerant oil before installing.

-

Always use correct size O-ring.

-

During installation, ensure proper seat in groove.

-

Keep work area, components and O-rings clean.

Relays and Modules - HVAC > < High Pressure Sensor / Switch, HVAC|Service and Repair