audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Service Port HVAC|Locations|Page 4001 > < Low Pressure Sensor / Switch, HVAC|Service and Repair
Page 1
background image

Service Port HVAC: Locations

1. A/C compressor (Zexel)

Low pressure connection
High pressure connection

Note:  The variable displacement A/C compressor varies piston stroke and output depending on load requirements and suction pressure.

CAUTION:  Discharge A/C refrigerant system before removing A/C compressor speed sensor.

2. A/C compressor speed sensor
3. A/C compressor clutch

CAUTION:  Remove the drain plug only after the compressor has been removed. It is used only to drain oil from old compressor and to check oil
level in a new compressor

4. Oil drain plug

WARNING:  Discharge A/C refrigerant system before removing pressure relief valve.

5. Pressure relief valve
6. Service valve (high pressure)

For A/C refrigerant high pressure switch
Remove switch and connect A/C high pressure gauge when checking pressures, discharging, evacuating or charging system

Note:  For checking system pressure, remove A/C refrigerant high pressure switch and reconnect to connector.

7. A/C refrigerant high pressure switch 

8. Condenser

9. Service valve (high pressure)

For A/C high pressure switch
Remove switch and connect A/C high pressure gauge when checking pressures, discharging, evacuating or charging system

10. A/C refrigerant high pressure switch 
11. Refrigerant line connection
12. Restrictor

Service Port HVAC|Locations|Page 4001 > < Low Pressure Sensor / Switch, HVAC|Service and Repair