audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Checking Control Function With Scan Tool|Page 1980 > < Checking Control Function With Scan Tool|Page 1978
Page 2
background image

If circuit is NOT open:

-

Switch DVOM to 10A (DC) measuring range.

Heated Oxygen Sensor Connector

-

Connect additional test cable VW 1315 A/1 to harness connector position 2.

-

Start engine and let idle.
^

Must be 0.5 - 3.0 amps.

Note:

Current decreases as sensor temperature increases.

If specified value is NOT obtained:

-

Replace HO2S sensor probe.

Checking Control Function With Scan Tool|Page 1980 > < Checking Control Function With Scan Tool|Page 1978