audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Rearview Camera System Overview, Through October 31, 2008|Page 7038 > < Rearview Camera System Overview, Through October 31, 2008|Page 7036
Page 3
background image

9

Measuring field of calibration platform

‹› Distance to rear wheel axle 1.47 m - 1.90 m - dimension A  -

Setting up measuring device

-

Check which hole circle the rims have.

-

Equip wheel pick-ups appropriately.

-

To do so, secure three wheel bolt adapters in the hole circle to each wheel pick-up.

-

Attach paddles to both wheel pick-ups and secure them with clamping screw.

-

Set the wheel pick-ups on to wheel mounting bolts at the rear wheels. 

When doing this, the wheel pick-ups are positioned by the " O-rings" in the adapters and held in place.

‹› Attach wheel pick-ups onto wheels so that any installed "anti-theft " wheel mounting bolts are not connected to the wheel pick-ups.

-

Adjust paddle with aid of lock screws so that they move freely just above the floor.

Make sure paddles move easily.

-

Position the calibration platform behind the vehicle at a distance of 1.47 m to 1.90 m to the rear wheels, see - dimension A - in the illustration.

-

Bring calibration platform to a horizontal position.

-

To do so, twist plastic feet under calibration platform so that air bubble in spirit level is located exactly in the center of the indicator - arrow -.

Rearview Camera System Overview, Through October 31, 2008|Page 7038 > < Rearview Camera System Overview, Through October 31, 2008|Page 7036