audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Magnesium|Page 2029 > < Magnesium|Page 2027
Page 9
background image

-

Generate vacuum using hand vacuum pump.

‹› The intake flaps are opened.

‹› If the intake flaps are not opened, they could have seized when installing the lower section of the intake manifold in the cylinder head.

-

Push the intake manifold lower section evenly onto the injection valves.

-

Tighten the bolts on the intake manifold lower section diagonally. 

‹› Intake manifold tightening specification. Refer to => [ Plastic Intake Manifold, from MY 2009 Assembly Overview ] See: Plastic Intake Manifold,

from MY 2009 Assembly Overview

-

Remove the hand vacuum pump from the connection on the vacuum diaphragm for the intake manifold flaps.

-

Counterhold the threaded connection and tighten the fuel high pressure line union nut on the high pressure pump.

-

Tighten the union nut - 3 - while counterholding the threaded connection.

‹› Tightening Specifications High pressure pump. Refer to => [ High Pressure Pump Assembly Overview ] See: Powertrain Management/Fuel

Delivery and Air Induction/Fuel Pump/Service and Repair/High Pressure Pump Assembly Overview

-

Make sure the high pressure line is free of tension.

Fuel Injectors

Special tools, testers and auxiliary items required

Magnesium|Page 2029 > < Magnesium|Page 2027