Connect an assisting hose - arrow - to pressure gauge and hold it in a measuring container.

-

Open shut-off valve of pressure gauge.

‹› The lever points in the flow direction.

-

Bleed fuel system by pressing remote control briefly.

-

Close shut-off valve of pressure gauge.

‹› Lever stands perpendicular to direction of flow - arrow -. 

-

Hold the switch of the remote control until no more pressure increase is observed on the fuel pressure gauge.

‹› Specified value: approximately 5.5 bar (4.5 to 6.5 bar) positive pressure 

If the specification is not obtained:

-

Check the fuel pump delivery quantity.

Checking residual pressure:

-

Check for leaks and residual pressure by observing pressure drop on pressure gauge.

‹› After 10 minutes there must be a residual pressure of at least 3 bar. 

If the residual pressure drops below 3 bar:

‹› Check connection between fuel pressure gauge and fuel line for leaks. 