audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Left Center Vent Motor|Page 6185 > < Left Center Vent Motor|Page 6183
Page 1
background image

Air Door Actuator / Motor: Removal and Replacement
Recirculation Door Motor

Door Motors

Recirculation Door Motor

‹› Perform Basic Setting of A/C system after installing the control motor. Refer to Vehicle diagnosis, testing and information system VAS 5051 in

the "guided fault finding" function.

‹› Using the functions "Output diagnostic test mode" and " Basic setting", the activation of A/C system electrical components can be tested if

necessary (e.g. allocation test). Refer to Vehicle diagnosis, testing and information system VAS 5051 in the "guided fault finding" function. 

‹› In the event of problems with moisture in passenger compartment, additionally check recirculated-air door (must close completely).

Removing

-

Move the passenger seats as far back as possible.

-

Switch off ignition.

-

Remove glove compartment. 

-

Loosen the wiring harness - E - from the air intake housing.

-

Remove the screws - B -.

-

Disconnect the control motor shaft- C - from the air recirculation door shaft - D -.

-

Mark the connector - A - if necessary (to rule out an interchange in the event several connectors are disconnected at the same time).

-

Disconnect the electrical connection - A -.

Installing

Installation is carried out in the reverse order, when doing this note the following.

-

Connect the connector - A -.

-

Insert the control motor shaft - C - into the air recirculation door shaft - D -.

‹› The control motor does not have a stop; therefore the control motor shaft - C - can be inserted into the air recirculation door shaft - D - at any

position.

-

Install the bolts - B -.

Left Center Vent Motor|Page 6185 > < Left Center Vent Motor|Page 6183