audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Procedures|Page 6385 > < Procedures|Page 6383
Page 3
background image

-

Loosen the locking mechanism - C - and remove the cover for the refrigerant lines leading to the evaporator - B -. 

-

Disconnect both refrigerant lines leading to the evaporator - A - and - B - at the location identified with - E - using Pliers for Unplugging A/C
Pipes (T40147).

-

Loosen the disconnected refrigerant lines - C - and - D - from the grommet - F - and remove both refrigerant lines.

-

Bend the part of the refrigerant line - A - (which is already on the evaporator) to the right (to the evaporator) so that it does not interfere when
removing the evaporator.

-

Remove the glove compartment. 

-

Remove the air intake housing. Refer to => [ A/C Unit Air Intake Housing ] See: Air Register/Service and Repair. 

-

Cut the housing wall - A - (on the right side of the A/C unit) using a sharp knife (for example, a strong carpet knife with a point; the blade must be
secure and the handle must be strong.) along the marked cutting line from the A/C unit.

Procedures|Page 6385 > < Procedures|Page 6383