Check O-ring seals for proper seating in grooves - arrows - on respective mount.

-

Check the fitting pin - A - (not installed on all connections) and refrigerant line connections - B - - E - and - F - for damage and proper seating.

-

Tighten the screws - D -.

‹› Tightening specification: 9 Nm.

-

Install the cover on the lock carrier. 

-

Evacuate and fill the refrigerant circuit. 

-

Install the remaining components.

-

Check DTC memory of A/C control head Climatronic Control Module (J255) and erase any displayed malfunction if necessary. Refer to Vehicle
Diagnosis, Testing and Information System VAS 5051 in "Guided Fault Finding" function.

-

Operate the A/C system after filling the refrigerant circuit. Refer to => [ Operating A/C System after Filling Refrigerant Circuit ] See: Description
and Operation/A/C Refrigerant System.

‹› Note the information regarding operating the A/C system after filling.