audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Receiver Dryer|Service and Repair|Page 6511 > < Receiver Dryer|Service and Repair|Page 6509
Page 3
background image

‹› Seal open connections on reservoir and condenser with suitable caps (to prevent dirt and moisture from entering).

Installing

Installation is done is reverse order, observe the following:

‹› Note the installation instructions for O-ring seals. Refer to => [ Refrigerant Circuit O-Ring Seals ] See: Description and Operation/Refrigerant

Circuit.

‹› Keep the reservoir closed as long as possible. Only remove the cape immediately prior to installation (reservoir contains a desiccant bag which

soon becomes saturated with moisture and thus unusable when reservoir is open). 

-

Clean the condenser surface - C -.

-

Check the connections on the condenser and on the reservoir for damage.

-

Replace the seals - D - and the O-ring seals - E - ; version.

-

Coat O-ring seals lightly with refrigerant oil before installing. Refer to => [ Refrigerant Circuit O-Ring Seals ] See: Description and
Operation/Refrigerant Circuit.

-

Check O-ring seals for proper seating in grooves - arrows - on respective mount.

-

Mount the reservoir - B - on the condenser and tighten the screws.

‹› Tightening specification: 10 Nm

-

Pull the protective sleeve - A - over the connection. 

Vehicles with charge air cooler installed under the condenser. 

-

Install the condenser. Refer to => [ Condenser ] See: Condenser HVAC/Service and Repair. 

All:

-

Install the front noise insulation. 

-

Install the air guide on the air filter housing flange.

-

Install the cover on the lock carrier.

-

Evacuate and fill the refrigerant circuit.

-

Install the remaining components.

-

Check DTC memory of A/C control head Climatronic Control Module (J255) and erase any displayed malfunction if necessary. Refer to Vehicle

Receiver Dryer|Service and Repair|Page 6511 > < Receiver Dryer|Service and Repair|Page 6509