audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Disconnecting and Connecting Refrigerant Lines From Compressor|Page 1221 > < Disconnecting and Connecting Refrigerant Lines From Compressor
Page 2
background image

-

Remove the bolts - 1 - and - 2 -. 

-

Remove refrigerant lines from A/C compressor.

‹› Close open lines and connections on A/C compressor using suitable caps (to prevent possible penetration of dirt and moisture).

Installing

Installation is done is reverse order, observe the following:

-

Replace the O-ring seals - D - and - C - version.

‹› Do not use the O-rings from the sealing caps that are installed on the connections in the replacement compressor when installing the lines.

‹› Note the installation instructions for O-ring seals. Refer to => [ Refrigerant Circuit O-Ring Seals ] See: Heating and Air Conditioning/Description

and Operation/Refrigerant Circuit.

-

Check the guide ring - F - on the connections for both refrigerant lines - B - and - C - for damage. 

-

Clean the refrigerant line and compressor connections and check for damage.

-

Coat O-ring seals lightly with refrigerant oil before installing. Refer to => [ Refrigerant Circuit O-Ring Seals ] See: Heating and Air
Conditioning/Description and Operation/Refrigerant Circuit.

-

Insert the respective O-ring seal - D - and - E - in the groove - G - on the connections for both refrigerant lines - B - and - C -.

-

Insert both refrigerant line into each connection on the compressor. 

Disconnecting and Connecting Refrigerant Lines From Compressor|Page 1221 > < Disconnecting and Connecting Refrigerant Lines From Compressor