Page 1
background image

Hose/Line HVAC: Service and Repair
Disconnecting and Connecting Refrigerant Lines, Quick-Release Couplings

A/C Compressor

Disconnecting and Connecting Refrigerant Lines, Quick-Release Couplings

Special tools, testers and auxiliary items required

‹› Release Tool for Air Conditioner Couplings (T40149)

Removing

-

Switch off ignition.

-

Drain the refrigerant circuit. 

‹› Depending on the allocation of the service connection an on the refrigerant line, and on the version of the vehicle, it may be necessary to remove

the additional reinforcement on the left suspension strut dome so that the service coupling of the service station can be connected (for example, on
the Audi Q5). 

-

Clean the refrigerant lines - A - and - C - in the area of the quick acting coupling connectors.

-

Clean the refrigerant lines - A - and - C - in the area of the quick acting coupling connectors with a silicone-free lubricant.

‹› The refrigerant lines adhere to the O-ring seal with the A/C is used; loosen the O-ring seal before mounting the release tool for air conditioner

couplings, for example by pulling and pushing the refrigerant lines; never twist the refrigerant lines.

-

Press the refrigerant lines - A - and - C - by hand all way into the connecting piece - B - of the refrigerant line with the inner heat exchanger.

-

Connect the Release Tool for Air Conditioner Couplings (T40149/1) to the refrigerant line - A - all the way (you should hear and feel the
mounting ring open), when doing this, the retaining with will expand.

-

Remove the refrigerant line - A - using the release tool for air conditioner coupling from the connector piece - B - of the refrigerant line with inner
heat exchanger.

Disconnecting and Connecting Refrigerant Lines From Compressor|Page 1223 > < Disconnecting and Connecting Refrigerant Lines From Compressor|Page 1221