Oxygen Sensor: Testing and Inspection
Oxygen Sensor 2 after Catalytic Converter, Checking

Oxygen Sensor 2 after Catalytic Converter, Checking

‹› Oxygen Sensor (O2S) 2 (behind Three Way Catalytic Converter (TWC)) Heater (Z30) is part of Oxygen Sensor (O2S) 2 Behind Three Way

Catalytic Converter (TWC) (G131) and cannot be serviced separately.

‹› When servicing terminals in harness connector of Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G131), use only

gold-plated terminals.

Special tools, testers and auxiliary items required

‹› Multimeter.

‹› Wiring diagram.

Test requirements

‹› Fuse (SB9) OK.

‹› Battery voltage at least 12.5 volts.

‹› All electrical consumers such as, lights and rear window defroster, switched off.

‹› Vehicles with automatic transmission, shift selector lever into position " P" or "N".

‹› A/C switched off.

‹› Ground (GND) connections between engine/transmission/chassis OK.

‹› Ignition switched off.

Test procedure

-

Perform a preliminary check to verify the customers complaint. Refer to => [ Preliminary Check ] See: Testing and Inspection/Scan Tool Testing
and Procedures/Preliminary Check.

Start diagnosis

-

Remove the engine compartment trim.

-

Remove the engine cover - 2 -.

-

Remove the air filter housing bolts - arrows -.