audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Heated Oxygen Sensor 1 before Catalytic Converter, Checking|Page 3036 > < Heated Oxygen Sensor 1 before Catalytic Converter, Checking|Page 3034
Page 1
background image

Oxygen Sensor: Testing and Inspection
Oxygen Sensor 2, Checking

Oxygen Sensor 2, Checking

The following procedure is used to diagnose Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G131) which is controlled by
the Motronic Engine Control Module (ECM) (J623).

‹› When servicing the electrical harness connector terminals of the Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G131) ,

use only gold-plated terminals.

Special tools, testers and auxiliary items required

‹› Multimeter.

‹› Wiring diagram.

Test requirements

‹› Fuse (SB9) OK.

‹› Oxygen Sensor (O2S) 2 (behind Three Way Catalytic Converter (TWC)) Heater (Z30) OK.

‹› Battery voltage at least 12.5 volts.

‹› All electrical consumers such as, lights and rear window defroster, switched off.

‹› Vehicles with automatic transmission, selector lever in position " P" or "N".

‹› A/C switched off.

‹› Ground (GND) connections between engine/transmission/chassis OK.

‹› Exhaust system between catalytic converter and cylinder head properly sealed.

‹› Coolant Temperature at least 80° C.

Function test

-

Perform the function test located in diagnostic mode 06. => [ Diagnostic Mode 06 - Read Test Results for Specific Diagnostic Functions ] See:
Testing and Inspection/Scan Tool Testing and Procedures/Diagnostic Mode 01 - 09/Diagnostic Mode 06 - Read Test Results for Specific
Diagnostic Functions.

If specified values are obtained:

-

End diagnosis and switch the ignition off.

If the specified values are not obtained:

Test procedure

-

Perform a preliminary check to verify the customers complaint. Refer to => [ Preliminary Check ] See: Testing and Inspection/Scan Tool Testing
and Procedures/Preliminary Check.

Start diagnosis

-

Remove the engine compartment trim.

Heated Oxygen Sensor 1 before Catalytic Converter, Checking|Page 3036 > < Heated Oxygen Sensor 1 before Catalytic Converter, Checking|Page 3034