Oxygen Sensor: Service and Repair
Heated Oxygen Sensor in Front of Catalytic Converter and Oxygen Sensor Behind Three Way
Catalytic Converter, Cylinder Bank 1

Heated Oxygen Sensor in Front of Catalytic Converter and Oxygen Sensor Behind Three Way Catalytic Converter, Cylinder Bank 1

Special tools, testers and auxiliary items required

‹› Ring Spanner 7-Piece Set for Oxygen Sensor (3337)

Removing

‹› During installation, all cable ties must be re-installed at the same location.

-

Remove the engine cover.

-

Disconnect electrical connector - 1 - on Mass Air Flow (MAF) Sensor (G70).

-

Disconnect the vacuum line - 3 - to the air guide pipe.

CAUTION!
Risk of violating emissions legislation.

‹› Do not open hose connection - 2 -!

-

Loosen the clamps - 4 -, open the clips - arrows - and move the air guide hose to the side with the crankcase ventilation hose still connected - 2 -.

-

Remove affected electrical connector from bracket and disconnect it.