Checking primary voltage

-

Crank the engine.

-

Using a multimeter, check the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) electrical harness connector terminals
3 to 4 for voltage.

Specified value: 0.400 to 0.500 Volts

-

Switch the ignition off.

If the specified value was obtained:

-

Replace the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130).

If the specified value was not obtained:

Checking wiring

If the manufacturers test box is being used, perform the following step.

-

Install the test box.

If the manufacturers test box is not being used, perform the following step.

-

Remove the Motronic Engine Control Module (ECM) (J623). Refer to => [ Engine Control Module, Replacing ] See: Engine Control
Module/Service and Repair/Engine Control Module, Replacing.

-

Using a Multimeter, check the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) electrical harness connector terminals

Heated Oxygen Sensor 1 before Catalytic Converter, Checking|Page 3245 > < Heated Oxygen Sensor 1 before Catalytic Converter, Checking|Page 3243