S5 Quattro Coupe V8-4.2L (CAUA) (2009)
‹› Left secondary air combination valve shown. The right secondary air combination valve is similar.
-
Remove the vacuum hose - 3 - from secondary air injection (AIR) combination valve.
-
Press the release buttons in and remove the secondary air hose - 4 -.
-
Connect a hand vacuum pump on vacuum connection - 1 - of the secondary air combination valve to be tested.
-
Connect a suitable assisting hose to secondary air combination valve - 2 -.
-
Blow into assisting hose using light pressure (do not use pressurized air).
The secondary air combination valve must remain closed preventing air from passing through.
-
Operate the hand vacuum pump to create a vacuum
The secondary air combination valve must open allowing air to pass through.