audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Combination Valve, Checking|Page 3328 > < Combination Valve, Checking
Page 2
background image

‹› Left secondary air combination valve shown. The right secondary air combination valve is similar.

-

Remove the vacuum hose - 3 - from secondary air injection (AIR) combination valve.

-

Press the release buttons in and remove the secondary air hose - 4 -.

-

Connect a hand vacuum pump on vacuum connection - 1 - of the secondary air combination valve to be tested.

-

Connect a suitable assisting hose to secondary air combination valve - 2 -.

-

Blow into assisting hose using light pressure (do not use pressurized air).

The secondary air combination valve must remain closed preventing air from passing through.

-

Operate the hand vacuum pump to create a vacuum 

The secondary air combination valve must open allowing air to pass through.

Combination Valve, Checking|Page 3328 > < Combination Valve, Checking