Checking internal resistance

-

Using a multimeter, check terminals 1 to 2 of the Fuel Injector to be tested for resistance.

Specified value: 12.0 to 20.0 ohms (at approx. 20° C)

If the specified value was not obtained:

-

Replace the faulty Fuel Injector.

If the specified value was obtained:

Checking activation

-

Connect a diode test lamp (12V) to the Fuel Injector electrical harness connector terminals 1 and 2 of the Fuel Injector to be tested.