audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Heated Oxygen Sensor 1 before Catalytic Converter, Checking|Page 855 > < Heated Oxygen Sensor 1 before Catalytic Converter, Checking|Page 853
Page 3
background image

Checking primary voltage

-

Switch the ignition on.

-

Using a multimeter, check the Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G131) electrical harness connector
terminals 3 to 4 for voltage.

Specified value: 0.400 to 0.500 Volts

-

Switch the ignition off.

If the specified value was obtained:

-

Replace the Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G131).

If the specified value was not obtained:

Checking wiring

If the manufacturers test box is being used, perform the following step.

-

Install the test box.

If the manufacturers test box is not being used, perform the following step.

-

Remove the Motronic Engine Control Module (ECM) (J623). Refer to => [ Engine Control Module, Replacing ] See: Powertrain
Management/Computers and Control Systems/Engine Control Module/Service and Repair/Engine Control Module, Replacing.

-

Using a Multimeter, check the Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G131) electrical harness connector

Heated Oxygen Sensor 1 before Catalytic Converter, Checking|Page 855 > < Heated Oxygen Sensor 1 before Catalytic Converter, Checking|Page 853