audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Electrical - Battery Testing Procedures|Page 4902 > < Battery - Testing/Charging On BDM Equipped Vehicles|Page 4897
Page 1
background image

Remote Battery Jumper Terminal: Technical Service Bulletins
Electrical - Battery Testing Procedures

27 08 02 

February 22, 2008

2011557/3

Supersedes Technical Service Bulletin Group 27 number 06-05 dated Oct. 24, 2006 to add model years and reformat.

Vehicle Information

Battery testing using 5051/5051B/5052 scan tool & charging using Midtronics InCharge 940 (INC-940) charging station - Q7

Condition

Testing the battery for all 2007  2009 Audi Q7 models must be performed using the VAS 5051, 5051B, or 5052 scan tools.

Technical Background

Remote jumper posts for charging are located under the hood on the driver's side.

Production Solution

Not applicable.

Service

1.

Follow the battery test instructions in the Guided Functions (GF) or Guided Fault Finding (GFF) test program found under address word 61,
Battery control. To enter battery test plan:

^

Select GFF >> Go To >> Function/Component Selection >> Body >> Electrical Equipment >> 01-On Board Diagnostics >> 61-Battery,
control >> J644-Energy Management Ctrl. Mo., functions >> Battery, test.

^

Select GF >> 61-Battery control >> Battery, test.

2.

The battery should be charged when installed and connected. This is the only means of ensuring charging content is taken into account in capacity
calculation of the Battery Energy Manager (BEM).

3.

Using the Midtronics InCharge 940 (INC-940) Battery Charging Station, connect the positive and negative cables to the corresponding remote
jumper posts under the hood on the driver's side.

Note: 

Electrical - Battery Testing Procedures|Page 4902 > < Battery - Testing/Charging On BDM Equipped Vehicles|Page 4897