S6 V8-4.2L (BBD) (2004)
-
Press -button.
-
Indicated on display:
-
Press the -1- button twice to select the function "Login-Procedure."
-
Indicated on display:
-
Confirm input using the -Q- button.
-
Indicated on display:
-
Press buttons -4-, -0-, -1-, -6- and -8- to select code number 40168. Press -Q- button to confirm input.
-
Indicated on display:
-
Press buttons -O- and -4- to select function 04 "Basic Setting"
-
Indicated on display:
-
Confirm input using the -Q- button.
-
Indicated on display:
-
Left-front bleeder valve must be open while booster pump is being activated.
-
Press buttons -0-, -O- and -2-.
-
Press -Q- button to confirm input and the hydraulic pump for traction control -V156- will be activated for 10 seconds. System in Basic Setting 2
-
Indicated on display:
-
Close bleeder valve again.
-
Press - button to return to beginning of troubleshooting procedure ("Select function XX" prompt). Rapid data transfer HELP