audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

With Generic Scan Tool|Page 5441 > < With Generic Scan Tool|Page 5439
Page 4
background image

(in relay- and fuse-carrier in E-Box, plenum chamber, position 3) for open circuit according to wiring diagram. 
-

Specified value: Wire resistance max 1.5 Ohms

 

-

Connect multimeter for voltage measurement as follows. 

3-pin relay carrier, E-box,

Measure to 

plenum chamber, position 3
Terminal

4

Engine Ground (GND)

-

Operate starter briefly. 
-

Specified value: approx. battery voltage

-

Switch ignition off. 

If specified value is not obtained:

-

Check wire connection from Secondary Air Injection (AIR) Pump Relay -J299- (in 3-pin relay carrier, E-box plenum chamber) to Fuel Pump (FP)
relay via Fuse -S234- (in fuse holder, position 34) for open circuit according to wiring diagram. 
-

Specified value: Wire resistance max 1.5 Ohm 

Check activation of the Secondary Air Injection (AIR) pump relay

-

Remove Secondary Air Injection (AIR) pump relay -2-.

-

Connect test box to wiring harness of Engine Control Module (ECM); ECM is not connected. See: Computers and Control Systems/Testing and
Inspection/Reading and Clearing Diagnostic Trouble Codes/Scan Tool Connecting/With Generic Scan Tool/Test Box, Connecting For Wiring
Test

With Generic Scan Tool|Page 5441 > < With Generic Scan Tool|Page 5439