audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Evaporative Emissions Hose > < EVAP Canister, Removing and Installing|Page 5501
Page 4
background image

 

-

Check the following wire connections for open circuit according to wiring diagram: 

Harness connector

Test box

Terminal

Socket

3

27 

4

53 

5 (signal wire)

29 

-

Specified value: Wire resistance max 1.5 Ohms

-

Also check wires for short circuit to each other as well as to B+ and Ground (GND). 
-

Specified value: infinity Ohms (no continuity)

-

If necessary, repair wire connection.

If no malfunctions are detected: 

-

Replace Mass Air Flow (MAF) sensor -G70-, item 5.

Final procedures 
After repair work, the following work steps must be performed in the mentioned sequence: 

1

-

Check DTC memory "Mode 3: Check DTC memory". See: Computers and Control Systems/Testing and Inspection/Scan Tool Testing and
Procedures/Scan Tool Testing/With Generic Scan Tool/Diagnostic Mode 3: Check DTC Memory

2

-

If necessary, erase DTC memory "Mode 4: Reset/erase diagnostic data". See: Computers and Control Systems/Testing and Inspection/Scan
Tool Testing and Procedures/Scan Tool Testing/With Generic Scan Tool/Diagnostic Mode 4: Reset/Erase Diagnostic Data

3

-

Generate readiness code. See: Computers and Control Systems/Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness
Codes/Audi Drive Cycle/Readiness Code/With Generic Scan Tool/Readiness Code, Generating

-

End diagnosis and switch ignition off.

Evaporative Emissions Hose > < EVAP Canister, Removing and Installing|Page 5501