audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

With Generic Scan Tool|Page 5584 > < With Generic Scan Tool|Page 5582
Page 3
background image

 

-

Secondary Air Injection (AIR) Pump Relay -2- (in 3-pin relay carrier, E-box plenum chamber) must engage and Secondary Air Injection (AIR)
Pump Motor -V101- must run

A - Secondary Air Injection (AIR) Pump Motor runs: 

-

Check voltage supply of the Secondary Air Injection (AIR) pump relay.

-

Check activation of the Secondary Air Injection (AIR) pump relay. 

B - Secondary Air Injection (AIR) Pump Motor does not run: 

-

Check voltage supply of the Secondary Air Injection (AIR) pump motor.

Checking voltage supply of Secondary Air Injection (AIR) pump relay

-

Remove Secondary Air Injection (AIR) pump relay -2-.

-

Connect multimeter for voltage measurement as follows.

 

3-pin relay carrier, E-box,

Measure to 

plenum chamber position 3 
Terminal

8

Engine Ground (GND)

 

-

Specified value: approx. battery voltage

If specified value is not obtained:

-

Check wire connection from battery + (terminal 30) via Fuse for secondary air pump -S130- to Secondary Air Injection (AIR) Pump Relay -J299-

With Generic Scan Tool|Page 5584 > < With Generic Scan Tool|Page 5582