audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

With Generic Scan Tool|Page 5650 > < With Generic Scan Tool|Page 5648
Page 3
background image

-

Test wiring from socket 2 on connector via fuse to fuel pump relay for open circuit or short to Ground. Correct, if necessary.

If the specified value is achieved: 

-

Check Ground supply to engine control module.

Checking Ground connection

-

Connect hand-held multimeter for voltage measuring to sockets 2 and 3 of connector. 

-

Operate starter briefly. 
Specified value: approx. battery voltage

NOTE:  Engine control module Ground is present at socket 3 of the connector. 

If specified value is not attained: 

-

Check wiring connections.

-

Connect hand-held multimeter for voltage measuring to sockets 3 and 4 of connector.

-

Switch ignition on. 
Specified value: approx. 5 V

If specified value is not attained:

-

Check wiring connections.

Checking wiring to MAF sensor 

NOTE:  The signal wire is also checked during the wiring check. 

-

Connect test box VAG 1598/31 to wiring harness for engine control module; engine control module must not be connected. See: Computers and
Control Systems/Testing and Inspection/Scan Tool Testing and Procedures/Scan Tool Testing/With Manufacturer's Scan Tool/Scan Tool
Connecting and Initial Checks/Connecting VAG 1598/31 Test Box

With Generic Scan Tool|Page 5650 > < With Generic Scan Tool|Page 5648