audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

With Generic Scan Tool|Page 4335 > < With Generic Scan Tool|Page 4333
Page 1
background image

Air Flow Meter/Sensor: Testing and Inspection
With Manufacturer's Scan Tool

Mass Air Flow (MAF) sensor -G70-, checking 

Test conditions 

-

Coolant temperature at least 80 degrees C

Electrical consumers switched off (radiator fan must not run during the check) 

-

Air conditioner switched off 

-

Fuse for MAF sensor OK 

Checking function 

-

Connect Vehicle Diagnostic, Testing and Information System VAS 5051 or V.A.G 1551 Scan Tool and select engine electronics control module 1
with "Address word" 01. For this purpose, engine must be running at idle speed.

 

Indicated on display 

Rapid data transfer

HELP 

Select function XX

-

Press keys 0 and 4 for function "Introduction of basic setting" and confirm entry with Q key.

NOTE:  During basic setting, the Evaporative Emission (EVAP) canister purge regulator valve -N80- is closed and the air conditioning compressor is
switched off by the engine control module. 

Indicated on display

Basic setting

Enter display group number XXX

-

Press keys 0, 0 and 2 for "display group number 2" and confirm entry with Q key.  

Indicated on display

System in basic setting 2

->

1

2

3

4

-

Check specified results for recorded load.

Display Group 2

If specified value is attained: 

-

Press ->key. 

With Generic Scan Tool|Page 4335 > < With Generic Scan Tool|Page 4333