audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

With Generic Scan Tool|Page 4365 > < With Generic Scan Tool|Page 4363
Page 1
background image

Camshaft Position Sensor: Testing and Inspection
With Manufacturer's Scan Tool

Camshaft Position (CMP) sensor -G40- and Camshaft Position (CMP) sensor 2 - G163-, checking

The CMP sensor indicates the ignition position for cylinder 1. 

If the CMP sensor fails to function, the knock control is switched off and the ignition timing is retarded slightly because the signals can no longer be
assigned to the cylinders. 

Even without a signal from the CMP sensor, the engine will continue to run and can also be re started.

-

When a malfunction is detected, the engine control module produces one spark for each cylinder on every crankshaft revolution. 

-

The fact that the control module is out of phase by one engine revolution does not have any noticeable effect on the injection system. If this
happens, the fuel is injected "advanced" (when the intake valve is closed) instead of while the intake valve is open. This has only a minor influence
on the quality of the air/fuel mixture.

NOTE: 

-

Camshaft Position (CMP) sensor 2 -G163- is located at rear of left cylinder head (bank 2). 

-

Camshaft Position (CMP) sensor -G40- is located at front of right cylinder head (bank 1).

Checking actuation of CMP sensor 

For the following checks, use leads from adapter set VAG 1594. 

-

Push back rubber sleeve on relevant CMP sensor connector. 

-

Connect VAG 1527 diode test lamp to sockets 1 and 2 on CMP sensor connector from rear (connector remains attached to CMP sensor).

NOTE: Sockets are numbered accordingly on the back of the connector. 

-

Operate starter for a few seconds
Diode test lamp must flash briefly on each second engine revolution.

NOTE: Diode test lamps with a low current consumption continue to glow faintly between impulses from the engine control module (rather than going
out completely) and become much brighter when receiving an impulse.

If diode test lamp does not flash, check voltage supply. 

Checking power supply for CMP sensor 

-

Disconnect connector from relevant CMP sensor. 

-

Switch ignition on. 

With Generic Scan Tool|Page 4365 > < With Generic Scan Tool|Page 4363