audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Evaporator Drain Tube > < Procedures|Page 13779
Page 10
background image

‹› Connect the 2-pin harness connector to the Coolant Pump (V50) of the pump/valve unit only after bleeding the coolant circuit.

‹› The Coolant Pump (V50) (in the pump/valve unit) may only be operated after bleeding the coolant circuit.

‹› Dry running of pump in pump valve unit leads to destruction.

-

Fill and bleed cooling circuit.

‹› When bleeding coolant circuit, take special care to ensure complete bleeding of heat exchangers. If there are still air bubbles in the heat exchanger,

it may cause the customer to complain of insufficient heating performance in winter or different air temperature from vents at same setting in
regulated mode 

-

After bleeding the cooling system, check it to ensure it is sealed tight. In particular, note the connections between the coolant pipes and the heat
exchanger

-

Check the position of the grommets in the coolant pipe feeds through from the plenum chamber to the passenger area for proper seating.

-

After installation, check the grommet between engine compartment and plenum chamber at the coolant hose - C - for proper seating. 

-

Check the pump/valve unit, it may not make contact with other components (noises).

-

After bleeding the coolant circuit, connect the connectors -  D - to the Left Heat Regulation Valve (N175) and Right Heat Regulation Valve
(N176), and - E - to the coolant pump Coolant Pump (V50).

-

Evacuate and re-charge refrigerant circuit. 

-

After filling the refrigerant circuit, check the refrigerant line connection points in the plenum chamber and evaporator for leaks, e.g. using an
electronic leak detector.

-

Clean coolant residue from the plenum chamber.

-

Install the remaining removed components again in reverse order. 

-

Check the DTC memory for the Climatronic Control Module (J255) A/C control head and erase any faults displayed if necessary.

-

Operate the A/C system after filling the refrigerant circuit => [ A/C System, Operating after Filling Refrigerant Circuit ] See: Description and
Operation/A/C System, Operating after Filling Refrigerant Circuit

Evaporator Drain Tube > < Procedures|Page 13779