background image

-

Check the pump/valve unit, it may not make contact with other components (noises).

-

After bleeding the coolant circuit, connect the connectors -  D - to the Left Heat Regulation Valve (N175) and Right Heat Regulation Valve
(N176), and - E - to the coolant pump Coolant Pump (V50).

-

Evacuate refrigerant circuit and refill it.

-

After filling the refrigerant circuit, check the refrigerant line connection points in the plenum chamber and evaporator for leaks, e.g. using an
electronic leak detector. 

-

Clean coolant residue from the plenum chamber.

-

Install the remaining removed components again in reverse order. 

-

Check the DTC memory for the Climatronic Control Module (J255) A/C control head and erase any faults displayed if necessary.

-

Perform a basic setting and output diagnostic test mode on the A/C system.

-

Operate the A/C system after filling the refrigerant circuit => [ A/C System, Operating after Filling Refrigerant Circuit ] See: Description and
Operation/A/C System, Operating after Filling Refrigerant Circuit