Refrigerant: Service Precautions
Refrigerant Circuit, Draining

A/C and Refrigerant Safety Precautions

The assemblies and piping system of the air conditioner are filled with the following refrigerant:

1.1.1.2 Tetrafluoroethane(CF3-CH2F or CH2F-CF3)

Currently, this refrigerant is known under the following trade names R134a, H-FKW 134a, SUVA 134a and KLEA 134a (other trade names may be
used in other countries).

Refrigerant Circuit, Draining

Refrigerant is never to be allowed to escape into the atmosphere, but rather it is to be extracted from the refrigerant circuit using an extractor or
service station. The drained refrigerant will be locally recycled or is send to an environment-recycling place to the manufacturer (different or
additional laws may apply in individual companies). For this reason, bring the vehicle to a workshop that has the necessary tools and qualified
personnel.

If refrigerant R134a is released into the environment, it enhances the green house effect.

‹› Refrigerant R134a has far less of a greenhouse effect than R12.

‹› Because R-134a does not contain chlorine atoms, the major catalyst in ozone depletion, refrigerant R-134a has no ozone depletion potential.

Depletion of the ozone layer in the upper atmosphere is however only brought about by the splitting of carbon-chlorine bonds (as is the case, for
example, with refrigerant R12).

Disconnect the connector from the A/C Compressor Regulator Valve (N280) or from the A/C Pressure/Temperature Sensor (G395) after draining the
A/C system.

A/C Compressor Regulator Valve (N280) is then no longer activated and compressor runs at idle. Compressor is designed such that lubrication of
compressor components is guaranteed by way of an internal oil circuit at idle (provided there is sufficient refrigerant oil in the compressor).

Refrigerant Circuit, Draining|Page 13887 > < Refrigerant|Capacity Specifications|Page 13884