CAUTION!
Hose connectors - 4
 - must not be opened. Move the right air filter housing upper section, with the crankcase ventilation hose still connected, to
the side.

-

Loosen the hose clamp - 6 - and remove screws -  1, 2 and 3 -.

-

Remove right air filter housing upper section.

-

Disconnect electrical connector - arrow - on Mass Air Flow (MAF) Sensor (G70).

-

Remove the air filter lower section form the side connection.