audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Heated Oxygen Sensor and Oxygen Sensor Regulation Before Catalytic Converter, Checking|Page 6733 > < Heated Oxygen Sensor and Oxygen Sensor Regulation Before Catalytic Converter, Checking
Page 2
background image

-

Disconnect the black Heated Oxygen Sensor (HO2S) (G39) electrical harness connector - 1 -.

Checking primary voltage

-

Crank the engine.

-

Using a multimeter, check the Heated Oxygen Sensor (HO2S) (G39) electrical harness connector terminals 2 to 6 for voltage.

Heated Oxygen Sensor and Oxygen Sensor Regulation Before Catalytic Converter, Checking|Page 6733 > < Heated Oxygen Sensor and Oxygen Sensor Regulation Before Catalytic Converter, Checking