‹› Ground (GND) connections between engine/transmission/chassis OK.

‹› Exhaust system between catalytic converter and cylinder head properly sealed.

‹› Coolant Temperature at least 80° C.

Function test

-

Perform the function test located in diagnostic mode 06. Refer to => [ OBDMID 05 ($05): Oxygen Sensor

Monitor Bank 2 - Sensor 1 ] See: Testing and Inspection/Scan Tool Testing and Procedures/Diagnostic Modes 01 - 09/Diagnostic Mode 06 - Read Test
Results For Specific Diagnostic Functions.

If specified values are obtained:

-

End diagnosis and switch the ignition off.

If the specified values are not obtained:

Procedure

-

Raise the vehicle. 

-

Loosen the quick release fasteners - 1 - and -  2 - and remove the noise insulation panel.

-

Remove the screws - arrows - and the oxygen sensor electrical harness connector heat shield. 

Heated Oxygen Sensor and Oxygen Sensor Regulation Before Catalytic Converter, Checking|Page 6736 > < Heated Oxygen Sensor and Oxygen Sensor Regulation Before Catalytic Converter, Checking|Page 6734