Carefully pull Fuel Level Sensor 2 G169 -1 - and suction jet pump- 2 - partially out of fuel tank opening.
NOTE: When removing, be sure not to bend floater arm of Fuel Level Sensor 2 G169.
-
Unclip suction jet pump from locking flange.
-
Separate electrical connector- 1 -.
-
Release retaining tabs - arrows - with a screwdriver and remove Fuel Level Sensor 2 G169.
Installing
-
Tightening torque.
Installation is in reverse order of removal, noting following:
NOTE: Always replace seal and union nut.
-
Insert Fuel Level Sensor 2 G169 in guides on locking flange and press in until it engages.
-
Connect electrical connection and check that it is securely engaged.
-
Clip suction jet pump to locking flange so that it is audibly engaged.
-
Check whether fuel delivery line is connected to suction jet pipe with at least 3 cable ties.
NOTE: When inserting, be sure not to bend floater arm of Fuel Level Sensor 2 G169.
-
Carefully insert Fuel Level Sensor 2 G169 in fuel tank opening.
-
Install new locking flange seal dry.
-
Press locking flange down against spring pressure and bring it into installation position.