S6 Quattro Sedan V10-5.2L (BXA) (2007)
Checking internal resistance
-
Using a multimeter, check the Heated Oxygen Sensor (HO2S) 2 (G108) terminals 3 to 4 for resistance.
Specified value: 2.5 to 10.0 ohms (at approx. 20° C)
If the specification was not obtained:
-
Replace Heated Oxygen Sensor (HO2S) 2 (G108).
If the specification was obtained:
Checking voltage supply
Crank the engine.
-
Using a multimeter, check the Heated Oxygen Sensor (HO2S) 2 (G108) electrical harness connector terminal 4 to Ground (GND) for voltage.