audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Secondary Air Injection Solenoid Valve, Checking|Page 7367 > < Secondary Air Injection Solenoid Valve, Checking
Page 2
background image

Specified value: 450 to 1000 ohms.

If the specified value was not obtained:

-

Replace the Secondary Air Injection (AIR) Solenoid Valve (N112). 

If the specified value was obtained:

Checking voltage

Crank the engine.

-

Using a Multimeter, check the Secondary Air Injection (AIR) Solenoid Valve (N112) electrical harness connector terminal 1 to Ground (GND) for
voltage.

-

Switch the ignition off.

Specified value: battery voltage.

If the specified value was not obtained:

-

Check the wiring from the Secondary Air Injection (AIR) Solenoid Valve (N112) electrical harness connector terminal 1 to the Engine Component
Power Supply Relay (J757) terminal 2/87 for a short circuit to Ground (GND), or an open circuit. 

-

Check the electrical harness connector for damage, corrosion, lose or broken terminals.

-

If necessary, repair the wiring connection.

If no malfunctions are found in the wiring:

Secondary Air Injection Solenoid Valve, Checking|Page 7367 > < Secondary Air Injection Solenoid Valve, Checking