S6 Quattro Sedan V10-5.2L (BXA) (2007)
-
Disconnect the Camshaft Position (CMP) Sensor 3 (G300) electrical harness connector - 4 -.
-
Switch the ignition on.
-
Using a Multimeter, Check the Camshaft Position (CMP) Sensor 3 (G300) electrical harness connector terminals 1 to 3 for voltage.
Specified value: about 5.0 V
-
Switch the ignition off.
If the specification was not obtained:
Checking wiring
If the manufacturers test box is being used. Perform the following step.
-
Install the test box.
If the manufacturers test box is not being used. Perform the following step.
-
Remove the Motronic Engine Control Module (ECM) (J623). Refer to => [ Engine Control Module, Removing and Installing ] See: Computers
and Control Systems/Engine Control Module/Service and Repair/Engine Control Module, Removing and Installing.
-
Using a Multimeter, Check the Camshaft Position (CMP) Sensor 3 (G300) electrical harness connector to the Motronic Engine Control Module
(ECM) (J623) electrical harness connector T60a for an open circuit.