audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Heated Oxygen Sensor and Oxygen Sensor Regulation Before Catalytic Converter, Checking|Page 5941 > < Heated Oxygen Sensor and Oxygen Sensor Regulation Before Catalytic Converter, Checking|Page 5939
Page 3
background image

Checking internal resistance

-

Using a multimeter, check the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) terminals 1 to 2 for resistance.

Specified value: 1.0 to 20.0 ohms (at approx. 20° C)

If the specification was not obtained:

-

Replace the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130). 

If the specification was obtained:

Checking voltage supply

Crank the engine.

-

Using a multimeter, check the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) electrical harness connector terminal
1 to Ground (GND) for voltage. 

Heated Oxygen Sensor and Oxygen Sensor Regulation Before Catalytic Converter, Checking|Page 5941 > < Heated Oxygen Sensor and Oxygen Sensor Regulation Before Catalytic Converter, Checking|Page 5939