audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Heated Oxygen Sensor and Oxygen Sensor Regulation Before Catalytic Converter, Checking|Page 5966 > < Heated Oxygen Sensor and Oxygen Sensor Regulation Before Catalytic Converter, Checking|Page 5964
Page 11
background image

Checking internal resistance

-

Using a multimeter, check the Heated Oxygen Sensor (HO2S) 3 (G285) terminals 3 to 4 for resistance. 

Specified value: 2.5 to 10.0 ohms (at approx. 20° C)

If the specification was not obtained:

-

Replace Heated Oxygen Sensor (HO2S) 3 (G285).

If the specification was obtained:

Checking voltage supply

 Crank the engine.

-

Using a multimeter, check the Heated Oxygen Sensor (HO2S) (G39) electrical harness connector terminal 4 to Ground (GND) for voltage.

Heated Oxygen Sensor and Oxygen Sensor Regulation Before Catalytic Converter, Checking|Page 5966 > < Heated Oxygen Sensor and Oxygen Sensor Regulation Before Catalytic Converter, Checking|Page 5964