Connect multimeter between terminal - 3 - and - 4 - of harness connector for voltage measurement.

-

Switch ignition on.
-

Specified value: approx. battery voltage. 

If the specification is not obtained:

-

Repair open circuit in wiring according to wiring diagram.

Fuel Pump (FP) Control Module J538 activation, checking

-

Remove protective cap.

-

For voltage testing, connect the multimeter with measuring probes and connector adapters from the connector test set V.A.G 1594C between
clamp - 4 - and - 5 -, as shown in the illustration. The electrical connection remains connected.

NOTE:  Connector sockets are numbered respectively on the rear side of the connector.

-

Start engine.
-

Specified value at start and in idle: approx. 5.0 V. 

-

Depress accelerator pedal completely and then release it (brief throttle burst).
-

Specified value: The voltage value must first rise slightly, then fall and then rise again to the value previously read.

If the reading does not result as described: 

-

Switch off ignition.

-

Connect Test Box V.A.G 1598/42 to wiring harness with adapter cable V.A.G 1598/39-1 or V.A.G 1598/39-2 ; engine control module (ECM) is
not connected. Clamp test box Ground (GND) clip to battery negative terminal.

CAUTION:  To avoid damaging electronic components, set measuring range before connecting test leads and observe all test
requirements.

Fuel Pump Control Unit|Testing and Inspection|Page 853 > < Fuel Pump Control Unit|Testing and Inspection|Page 851