to the Motronic Engine Control Module (ECM) (J623) electrical harness connector T94a terminals for an open circuit.

Specified value: 1.5 ohms Max.

If the specification was not obtained:

-

Check the wiring for a short circuit to each other, Battery (+), and Ground (GND).

-

Check the electrical harness connector for damage, corrosion, lose or broken terminals.

-

If necessary, repair the faulty wiring connection.

If no malfunction is found in the wiring:

-

Replace the Motronic Engine Control Module (ECM) (J623). Refer to => [ Engine Control Module, Removing and Installing ] See: Powertrain
Management/Computers and Control Systems/Engine Control Module/Service and Repair/Engine Control Module, Removing and Installing.

Assembly is performed in the reverse order of removal.

Final procedures

After repair work, the following work steps must be performed in the following sequence:

1. Check the DTC memory. Refer to => [ Diagnostic Mode 03 - Read DTC Memory ] See: Powertrain Management/Computers and Control

Systems/Testing and Inspection/Scan Tool Testing and Procedures/Diagnostic Modes 01 - 09/Diagnostic Mode 03 - Read DTC Memory.

2. If necessary, erase the DTC memory. Refer to => [ Diagnostic Mode 04 - Erase DTC Memory ] See: Powertrain Management/Computers and

Control Systems/Testing and Inspection/Scan Tool Testing and Procedures/Diagnostic Modes 01 - 09/Diagnostic Mode 04 - Erase DTC Memory. 

3. If the DTC memory was erased, generate readiness code. Refer to => [ Readiness Code ] See: Powertrain Management/Computers and Control

Systems/Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes.

-

End of diagnosis.

Oxygen Sensor 2 Behind Three Way Catalytic Converter 

The following procedure is used to diagnose Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G131) which is controlled by
the Motronic Engine Control Module (ECM) (J623).

‹› When servicing the electrical harness connector terminals of the Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G131) ,

use only gold-plated terminals.

Heated Oxygen Sensor and Oxygen Sensor Regulation Before Catalytic Converter, Checking|Page 2747 > < Heated Oxygen Sensor and Oxygen Sensor Regulation Before Catalytic Converter, Checking|Page 2745