Page 7
background image

-

Disconnect the black Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G131) electrical harness connector- 6 -.

Checking internal resistance

-

Using a multimeter, check the Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G131) terminals 1 to 2 for resistance.

Specified value: 1.0 to 20.0 ohms (at approx. 20° C)

If the specification was not obtained:

-

Replace the Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G131). 