S6 Quattro Sedan V10-5.2L (BXA) (2007)
If the specification was obtained:
Checking voltage supply
Crank the engine.
-
Using a multimeter, check the Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G131) electrical harness connector
terminal 1 to Ground (GND) for voltage.
Specified value: Battery voltage.
Switch the ignition off.
If the specification was not obtained:
-
Check the wiring from the Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G131) electrical harness connector terminal 1
to the Engine Component Power Supply Relay (J757) socket 2/87 for a short circuit to each other, Ground (GND) or an open circuit.
-
Check the electrical harness connector for damage, corrosion, lose or broken terminals.
-
If necessary, repair the faulty wiring connection.
If the specification was obtained:
Checking Ground (GND) activation
If the manufacturers test box is being used. Perform the following step.
-
Install the test box.
If the manufacturers test box is not being used. Perform the following step.
-
Remove the Motronic Engine Control Module (ECM) (J623). Refer to => [ Engine Control Module, Removing and Installing ] See: Powertrain
Management/Computers and Control Systems/Engine Control Module/Service and Repair/Engine Control Module, Removing and Installing.
-
Using a multimeter, check the Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G131) electrical harness connector to the
Motronic Engine Control Module (ECM) (J623) electrical harness connector T94a for an open circuit.