Function

Switches A/C clutch -N25- OFF if system suction pressure is too low (low refrigerant charge). This switch protects the compressor if the refrigerant
system is empty.

-

Switch located in right plenum.

-

Switch opens (compressor OFF): 1.45 - 1.6 bar (21 - 23 psi).

-

Switch closes (compressor ON): 2.9 - 3.4 bar (42 - 49 psi).

Removing And Installing

-

Remove plenum tray.

-

Remove electrical connector and unscrew low pressure switch -F73-. Refrigerant system remains closed (Schrader valve under switch).

-

Install new O-ring -A- (8.9 mm x 1.8 mm), lubricate with refrigerant (PAG) oil and ensure proper seating in groove.

-

Torque switch to 5 Nm (44 in lb).

-

Install plenum tray.