audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Oxygen Sensor Heaters After Catalytic Converter, Checking|Page 3223 > < Oxygen Sensor Heaters After Catalytic Converter, Checking|Page 3221
Page 3
background image

Specified value: 1.0 to 20.0 ohms (at approx. 20 °C)

If the specification was not obtained:

-

Replace the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130). 

If the specification was obtained:

Checking voltage supply

Crank the engine.

-

Using a multimeter, check the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) electrical harness connector terminal
1 to Ground (GND) for voltage. 

Specified value: Battery voltage.

Switch the ignition off.

If the specification was not obtained:

-

Check the wiring from the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) electrical harness connector terminal 1 to
the Engine Component Power Supply Relay (J757) socket 2/87 for a short circuit to each other, Ground (GND) or an open circuit.

Oxygen Sensor Heaters After Catalytic Converter, Checking|Page 3223 > < Oxygen Sensor Heaters After Catalytic Converter, Checking|Page 3221