audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Oxygen Sensor Heaters After Catalytic Converter, Checking|Page 3640 > < Oxygen Sensor Heaters After Catalytic Converter, Checking|Page 3638
Page 5
background image

-

End of diagnosis.

Oxygen Sensor 2 Heater

The following procedure is used to diagnose Oxygen Sensor (O2S) 2 Heater (Z28) for Heated Oxygen Sensor (HO2S) 2 (G108) which is controlled
by the Motronic Engine Control Module (ECM) (J623).

‹› When servicing electrical harness connector terminals for the Heated Oxygen Sensors, use only gold-plated terminals.

Special tools, testers and auxiliary items required

‹› Multimeter.

‹› Wiring diagram.

Test requirements

‹› Fuse (SC6) OK.

‹› Battery voltage at least 12.5 volts.

‹› All electrical consumers such as, lights and rear window defroster, switched off.

‹› Vehicles with automatic transmission, shift selector lever into position " P" or "N".

‹› A/C switched off.

‹› Ground (GND) connections between engine/transmission/chassis OK.

‹› Ignition switched off.

Procedure

-

Raise the vehicle. 

-

Loosen the quick release fasteners - 1 - and -  2 - and remove the noise insulation panel.

Oxygen Sensor Heaters After Catalytic Converter, Checking|Page 3640 > < Oxygen Sensor Heaters After Catalytic Converter, Checking|Page 3638