Perform the function test located in diagnostic mode 06. Refer to => [ OBDMID 10 ($0A): Oxygen Sensor

Monitor Bank 3 - Sensor 2 ] See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Scan Tool Testing and
Procedures/Diagnostic Modes 01 - 09.

If specified values are obtained:

-

End diagnosis and switch the ignition off.

If the specified values are not obtained:

Procedure

-

Raise the vehicle.

-

Loosen the quick release fasteners - 1 - and -  2 - and remove the noise insulation panel.

-

Disconnect the brown Oxygen Sensor (O2S) 3 Behind Three Way Catalytic Converter (TWC) (G287) electrical harness connector- 1 -.